MAINTENANCE
Scheduled Maintenance
Maintenance performed quarterly, annually and
every two years must be completed by a person
trained and qualified to perform maintenance on this
machine according to the procedures found in the
service manual for this machine.
Machines that have been out of service for more
than three months must receive the quarterly
inspection before they are put back into service.
MAINTENANCE
Check the Hydraulic Oil Level
Maintaining the hydraulic oil at the proper level is
essential to machine operation. Improper hydraulic
oil levels can damage hydraulic components. Daily
checks allow the inspector to identify changes in
oil level that might indicate the presence of
hydraulic system problems.
1 Be sure the platform is fully lowered.
2 Check the sight gauge on the side of the
hydraulic tank.
Result: The hydraulic oil level should be visible
in the middle of the sight gauge. Do not overfill.
Hydraulic oil specifications
Hydraulic oil type Dexron equivalent