MAINTENANCE
Check the Engine Oil Level
Maintaining the proper engine oil level is essential
to good engine performance and service life.
Operating the machine with an improper oil level
can damage engine components.
Check the oil level with the
engine off.
1 Check the oil level dipstick. Add oil as needed.
Kubota Engine DF-752-E2
Oil type 10W-30
Kubota Engine D-905 B-22
Oil type 10W-30
Perkins Engine 404C-11
Oil type 15W-40
Check the Batteries
Proper battery condition is essential to good engine
performance and operational safety. Improper fluid
levels or damaged cables and connections can
result in engine component damage and hazardous
conditions.
Bodily injury hazard. Batteries
contain acid. Avoid spilling or
contacting battery acid. Neutralize
battery acid spills with baking
soda and water.
1 Put on protective clothing and eye wear.
2 Be sure that the battery cable connections are
tight and free of corrosion.
3 Be sure that the battery hold-down bracket is
tight.
4 Remove the battery vent caps.
5 Check the battery acid level. If needed,
replenish with distilled water to the bottom of
the battery fill tube. Do not overfill.
6 Install the vent caps.