NI 5421 Specifications 26 ni.com
Markers
Table 9.
Specification Valu e Comments
Destinations 1. PFI<0..1> (SMB front panel connectors)
2. PFI<4..5> (DIGITAL DATA & CONTROL front panel
connector)
3. NI PXI-5421—PXI_Trig<0..6> (backplane connector)
NI PCI-5421—RTSI<0..7>
Quantity One Marker per Segment.
Quantum Marker position must be placed at an integer multiple of
four samples.
Width >150 ns. Refer to t
m2
at NI Signal Generators Help»
Devices»NI 5421»NI <bus>-5421»Waveform
Generation»Marker Events.
Skew
Destination
With Respect to
Analog Output
With Respect to
Digital Data
Output
Refer to t
m1
at
NI Signal
Generators
Help»Devices»
NI 5421»
NI <bus>-5421»
Waveform
Generation»
Marker Events.
PFI<0..1> ±2 Sample Clock
Periods
N/A
PFI<4..5> N/A <2 ns
NI PXI-5421
PXI_Trig<0..6>
NI PCI-5421
RTSI<0..6>
±2 Sample Clock
Periods
N/A
Jitter 20 ps rms