MAINTENANCE
Scheduled Maintenance
Maintenance performed quarterly, annually, semi-
annually and every two years must be completed
by a person trained and qualified to perform
maintenance on this machine according to the
procedures found in the service manual for this
machine.
Machines that have been out of service for more
than three months must receive the quarterly
inspection before they are put back into service.
Check the Engine Oil Level
(if equipped)
Maintaining the proper engine oil level is essential
to good engine performance and service life.
Operating the machine with an improper oil level
can damage engine components.
Check the oil level with the
engine off.
1 Check the oil level dipstick.
Result: The oil must touch the dipstick.
2 If oil is low, fill to the edge of the oil filler hole.
Honda GX160K1
Oil viscosity requirements
-4° to 100°F / -20° to 38°C 10W-30
Below 30°F / 0°C 5W-30
Above 50°F / 10°C 30W
Engine oil should have properties of API classification
SJ.