Genie Model 2022 User Manual Page 15

  • Download
  • Add to my manuals
  • Print
  • Page
    / 30
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 14
PN# 37026500123 02/26/2010 REV. 1
NOTE: Wall console will not operate until limits
are set.
NOTE: For Wall Console, wire and insulated
staples locate Bags 6 and 7 from Box 2.
1. Wall Console location.
Wall Console location should be in direct sight
of door.
It should be at least five feet (5') above floor to
prevent small children from operating door.
It must be away from any moving parts. (You
should NOT be able to reach the garage door
while standing at Wall Console.)
Wall Console board screw connections are
polarized, (+) positive and (-) negative.
2a. Wiring (If pre-wired).
Locate Wall Console pre-wired wire ends
(Fig. 3-1). (They should be located within the
guidelines mentioned above.)
Split and strip ends of wire (Fig. 3-2).
Fasten wire to Wall Console board screws on
back of Wall Console.
Striped wire to the + (plus) terminal.
White wire to the - (minus) terminal.
2b. Wiring (If NOT pre-wired).
Pick a convenient location for mounting
Wall Console using the guidelines mentioned
above (Fig. 3-1).
Run wire from power head to Wall Console
(Fig. 3-1).
Split and strip ends of wire (Fig. 3-2).
Fasten wire to Wall Console board screws
on
back of Wall Console.
Striped wire to the + (plus) terminal.
White wire to the - (minus) terminal.
WALL CONSOLE INSTALLATION
FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM
3
Verify there is NO power to the opener before
installing Wall Console wires and Wall Console.
WARNING
Staples which are too tight can cut or pinch wires.
Cut or pinched wires can cause the Wall Console
to stop working. When using the insulated staples,
make sure you fasten them only as tightly as
needed to hold the wire snugly.
CAUTION
FIG. 3-2 Splitting and stripping
.
FIG. 3-1 Wall Console wire routing
Wire from
power head
to Wall Console
Wall
Console
"Entrapment"
warning label
Separate
entry door
EXAMPLE ONLY!
This is an example of wire routing
when NOT pre-wired. Your wire
routing may be different.
1/2"
2"
15
Black
Striped
White
+
or
or
Use of any other wall control can cause the door to
operate unexpectedly and the light not to work.
Use only the included Wall Console.
WARNING
Page view 14