Genie TMZ-10 User Manual Page 19

  • Download
  • Add to my manuals
  • Print
  • Page
    / 34
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 18
Part No. 72896 Genie TMZ-50/30 & Genie TMZ-17/10 17
Operator's Manual
First Edition • Third Printing
Function Tests
1 Be sure the boom hold-down latches are
unlatched.
Setup
2 Position the machine below the desired work
area.
3 Set the parking brake.
4 Insert the key and turn to ground control.
5 Pull out the red Emergency Stop buttons at the
ground and platform controls.
Models with optional drive system: Also pull out
the red Emergency Stop button on the drive
control panel.
Machines with LED diagnostic readout: LED
should read ----.
Note: Machines with LED diagnostic readout
perform a self-check when the power is turned on.
The self-check takes about 5 seconds. Do not
touch the buttons of the ground control panel until
the self-check is done.
6 Push and hold the auto-level button. Push and
hold the extend outrigger button. The outriggers
will lower and adjust to level the machine and
raise the wheels slightly off the ground. Level
the machine using only the outriggers. Do not
use chocks, blocks or shims of any kind to level
the machine.
Function Tests
Do Not Operate Unless:
You learn and practice the principles of safe
machine operation contained in this operator's
manual.
1 Avoid hazardous situations.
2 Always perform a pre-operation
inspection.
3 Always perform function tests prior to
use.
Know and understand the function tests
before going on to the next section.
4 Inspect the workplace.
5 Only use the machine as it was intended.
Fundamentals
The Function Tests are designed to discover any
malfunctions before the machine is put into
service. The operator must follow the step-by-step
instructions to test all machine functions.
A malfunctioning machine must never be used. If
malfunctions are discovered, the machine must be
tagged and removed from service. Repairs to the
machine may only be made by a qualified service
technician, according to the manufacturer's
specifications.
After repairs are completed, the operator must
perform a pre-operation inspection and function
tests again before putting the machine into service.