8
1
2
3
4
CONTACT REVERSE TEST
The Force and Limit settings on the previous page MUST be COMPLETED before Contact
Reverse testing.
1. Test.
Open garage door using wall console.
– Place a 2" x 4" board (laid flat) under center of garage door opening.
Close garage door using wall console.
When door contacts board, the door must stop (within 2 seconds) and reverse direction
returning to open position.
2. Adjustment.
If the door:
– Stops before it contacts the 2 x 4 board, it may simply be responding to an improperly set
down limit. Return to pages 6-7 and repeat steps 1 through 10 to correct down limit.
– Stops after contacting the 2 x 4 board and does not reverse it may need an adjustment to
the down limit. Return to pages 6-7 and repeat steps 1 through 10 to correct down limit.
Test again. Repeat as necessary until door reverses upon contacting board.
WARNING
A moving door can cause serious injury or death.
1. Keep people clear of opening while door is moving.
2. Do NOT allow children to play with opener, including
wall console, remote, or wireless keypad.
3. During programming, door opener could begin to run,
so stay away from moving door and its parts.
On Wall Console
PRESS and RELEASE
DOOR OPENS
PRESS and RELEASE
Once the Contact Reverse Testing is complete continue with Programming Remotes on the next page.