Genie INTELLIG 3024 User Manual Page 6

  • Download
  • Add to my manuals
  • Print
  • Page
    / 26
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 5
©2010 The Genie Company 01/27/2010
6
PROGRAM
SET
+
5 SECS
SETTING & TESTING LIMITS AND FORCE
The OPEN (UP) and CLOSE (DOWN) Door Limit positions are controlled by making
adjustments using the panel located on the bottom of the power head. Begin with
Step 1 and continue through Step 10. Door Force is set during the final Open/Close
cycle of these steps. The power head will automatically set door speed at slow if the
distance between limits is less than 6 feet.
A) CLOSE DOOR TRAVEL LIMIT
NOTE: You can start and stop door
movement using either buttons until
door is in correct open or closed position.
Watch door move
PROGRAMMING LIMITS & FORCE (Continuing from Installation Poster
if provided)
1
G
RAM
SE
+
PRESS and HOLD
5
PROGRAM
SET
+
PRESS and HOLD
SEE BOTH
Blue LEDs
come ON
SEE round
Blue LED
come ON
PR
OGRAM
SET
SEE round Blue
LED flashing
RELEASE
1
2 3
4
NOTE: If one or both LEDs come ON RED at this
time; Limits programming menu was not entered
properly. You must exit programming and restart.
To exit this mode:
A. Press
PROGRAM
SET
and release
B. Pause
C. Press
PROGRAM
SET
and release
D. Pause
E. Begin with Step 1 on this page. Restarting at
Step 1 will reset RED LEDs to BLUE.
PRESS and RELEASE
WARNING
Make sure doorway is in view and clear of obstacles
and people to avoid injury or damage to property.
DO NOT operate this unit from wall console before
LIMITS and FORCE are set. Severe damage to the
opener can occur.
Bullet MUST be engaged to carriage BEFORE setting
limits. See Installation Poster (if provided) or refer to
pages 12 and 18.
Please note that there is a 30 second timeout
between each programming step.
A programming timeout during these steps has
occured when two RED flashing LEDs appear.
In the event of a timeout please restart at Step 1.
NOT CE
O R C M UC D
U O N N H D
Travel door to FULL CLOSED position
RELEASE
PRESS and
RELEASE
SEE long Blue
LED come ON
If RED LED comes ON - STOP and
exit programming.
Page view 5
1 2 3 4 5 6 7 8 9 10 11 ... 25 26

Comments to this Manuals

No comments