TROUBLESHOOTING GUIDE -
POWER HEAD LED
FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM
Power head LED
Possible Problem Solution
Red LED
showing
Green LED
showing
OFF OFF Normal operation None required
Continuous ON Programming incomplete Complete programming
1 BLINK, Pause
(Repeat)
Transmitter has not learned Push transmitter button to program
(See section )
7
1 BLINK, Pause
(Repeat)
Limit Programming incomplete
Safe-T-Beam
®
sensor
obstruction going down
Door obstruction going down
Door obstruction going up
Set DOWN LIMIT programming
Check for obstruction, remove
Check for obstruction, remove.
Check door spring (See section )
Contact The Genie Company at
1-800-35-GENIE
10
2 BLINKS, Pause
(Repeat)
Limit Programming incomplete
Wire to power head or wire
connection at power head is
bad.
Sensors out of alignment
Continuous obstruction of
Safe-T-Beam
®
sensor
Set UP LIMIT programming
Check power head wiring, check
connections,
Replace or repair
Check Source & Sensor alignment
Check for obstruction of
Safe-T-Beam
®
sensor
3 BLINKS, Pause
(Repeat)
Limits set backwards Clear limits and reprogram
(See section )
6
4 BLINKS, Pause
(Repeat)
Wall button wire short
Wall button wires reversed
in power head connector.
Check button(s) and wiring.
Staples can cut insulation and shorts
wires. Replace Wall Control, repair or
replace wiring.
– Contact The Genie Company at
1-800-35-GENIE
Reverse wire placement in power
head connector. (See section )
3
5 BLINKS, Pause
(Repeat)
Chain/belt is too tight
Control system failure
Adjust chain/belt tension
(See section ).
– Contact The Genie Company at
1-800-35-GENIE
Contact Genie
®
authorized dealer for
service
1