FUNCTION TESTS
10 Push and hold the function enable button and
activate the platform down function.
Result: The platform should lower. The descent
alarm should sound while the platform is
lowering.
Test the Auxiliary Lowering
To test machines equipped with a
separate auxiliary lowering button
next to the ground control panel,
perform steps 11 through 13. For
machines that are not equipped with
a separate button, skip to step 14.
11 Push and hold the function enable button and
activate the platform up function. Raise the
platform approximately 2 feet / 60 cm.
12 Push and hold the auxiliary lowering button.
Result: The platform should lower. The descent
alarm will not sound.
13 Turn the key switch to platform control and go to
step 17.
Machines not equipped with a separate auxiliary
lowering button:
14 Push and hold the function enable button and
activate the platform up function. Raise the
platform approximately 2 feet / 60 cm.
15 Push and hold the function enable button.
Activate the down function.
Result: The platform should lower. The descent
alarm will not sound.
16 Turn the key switch to platform control.
1 Select a test area that is firm, level and free of
obstruction.
2 Be sure the battery pack is connected.
At the Ground Controls
3 Pull out the platform and ground red Emergency
Stop buttons to the on position.
4 Turn the key switch to ground control.
5 Observe the diagnostic LED
readout.
Result: The LED should look like the
picture at right.
Test the Emergency Stop
6 Push in the ground red Emergency Stop button
to the off position.
Result: No functions should operate.
7 Pull out the red Emergency Stop button to
the on position.
Test the Up/Down Functions
The descent alarm and the motion alarm sound at
60 beeps per minute and sound at the chassis. The
alarm that goes off when the machine is not level
sounds at 180 beeps per minute and sounds at the
chassis and in the platform.
8 Do not hold the function enable
button. Activate the platform up
function.
Result: No function should operate.
9 Push and hold the function enable button and
activate the platform up function.
Result: The platform should raise.