Genie Z34N-2100 Z-34 User Manual Page 23

  • Download
  • Add to my manuals
  • Print
  • Page
    / 36
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 22
Part No. 43654 Genie Z-34/22 & Genie Z-34/22N 21
Operator's Manual
Second Edition • Ninth Printing
OPERATING INSTRUCTIONS
Emergency Stop
Push in the red Emergency Stop button to the off
position at the ground or platform controls to stop
all machine functions.
Repair any function that operates when the red
Emergency Stop button is pushed in.
Selecting and operating the ground controls will
override the platform Red Emergency Stop button.
Auxiliary Controls
Use auxiliary power if the primary power source
fails.
1 Turn the key switch to ground or platform
control.
2 Pull out the red Emergency Stop button to the
on position.
3 Move the lift/drive select switch to the
appropriate position (if equipped) when
operating the auxiliary controls from the
platform.
4 Press down the foot switch when operating the
auxiliary controls from the platform.
5 Simultaneously hold the auxiliary power switch
on and activate the desired function.
The boom, steer and drive functions will operate
with auxiliary power.
Operation from Ground
1 Turn the key switch to ground control.
2 Pull out the red Emergency Stop button to
the on position.
3 Be sure both battery packs are connected
before operating the machine.
To Position Platform
1 Hold the function enable switch to either side.
2 Move the appropriate toggle switch according
to the markings on the control panel.
Drive and steer functions are not available from the
ground controls.
Machines equipped with Platform Level Control
Disable Function: The platform level toggle switch
will not operate when the boom is raised past the
drive speed limit switch.
Page view 22
1 2 ... 18 19 20 21 22 23 24 25 26 27 28 ... 35 36