14 Genie Z-34/22 & Genie Z-34/22N Part No. 43654
Operator's Manual Second Edition • Ninth Printing
Function Tests
Do Not Operate Unless:
You learn and practice the principles of safe
machine operation contained in this operator's
manual.
1 Avoid hazardous situations.
2 Always perform a pre-operation
inspection.
3 Always perform function tests prior to
use.
Know and understand the function tests
before going on to the next section.
4 Inspect the workplace.
5 Only use the machine as it was intended.
1 Select a test area that is firm, level and free of
obstruction.
At the Ground Controls
2 Turn the key switch to ground control.
3 Pull out the red Emergency Stop button to
the on position.
Result: The beacon (if equipped) should flash.
Test Emergency Stop
4 Push in the red Emergency Stop button to the
off position.
Result: All ground and platform control functions
should not operate.
5 Pull out the red Emergency Stop button to
the on position.
Fundamentals
The function tests are designed to discover any
malfunctions before the machine is put into
service. The operator must follow the step-by-step
instructions to test all machine functions.
A malfunctioning machine must never be used. If
malfunctions are discovered, the machine must be
tagged and removed from service. Repairs to the
machine may only be made by a qualified service
technician, according to the manufacturer’s
specifications.
After repairs are completed, the operator must
preform a pre-operation inspection and function
tests again before putting the machine into
service.