Page view 12
Part No. 56011 Genie Z-34/22 Bi-Energy 11
Operator's Manual
First Edition Fifth Printing
Maintenance
Observe and Obey:
Only routine maintenance items specified in
this manual shall be performed by the operator.
Scheduled maintenance inspections shall be
completed by qualified service technicians,
according to the manufacturer's specifications
and the requirements specified in the
responsibilities manual.
Check the Hydraulic Oil Level
Maintaining the hydraulic oil at the proper level is
essential to machine operation. Improper hydraulic
oil levels can damage hydraulic components. Daily
checks allow the inspector to identify changes in
oil level that might indicate the presence of
hydraulic system problems.
1 Be sure the boom is in the stowed position.
2 Visually inspect the oil level in the hydraulic
tank.
Result: The hydraulic oil level should be within
the FULL and ADD marks on the hydraulic tank.
3 Add oil if necessary.
Hydraulic oil specifications
Hydraulic oil type Refer to machine decal
Maintenance Symbols Legend
The following symbols have been
used in this manual to help
communicate the intent of the
instructions. When one or more of
the symbols appear at the
beginning of a maintenance
procedure, it conveys the meaning
below.
Indicates that tools will be required
to perform this procedure.
Indicates that new parts will be
required to perform this procedure.
Page view 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 30 31

Comments to this Manuals

No comments